Unistar-Sparco Computers SPARC Enterprise Servers XCP version 1050 Manual de usuario Pagina 40

  • Descarga
  • Añadir a mis manuales
  • Imprimir
  • Pagina
    / 48
  • Tabla de contenidos
  • MARCADORES
  • Valorado. / 5. Basado en revisión del cliente
Vista de pagina 39
30 SPARC Enterprise M4000/M5000 Servers Product Notes for XCP Version 1050 September 2007
6559504 Messages of the form nxge: NOTICE:
nxge_ipp_eccue_valid_check: rd_ptr = nnn
wr_ptr = nnn will be observed on the console
with the following cards:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
These messages can be safely ignored.
6568417 After a successful CPU DR deleteboard
operation, the system panics when the
following network interfaces are in use:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
Add the following line to /etc/system and
reboot the system:
set ip:ip_soft_rings_cnt=0
6589833 The DR addboard command might cause a
system hang if you are adding a Sun
StorageTek Enterprise Class 4Gb Dual-Port
Fibre Channel PCI-E HBA card (SGXPCIE2FC-
QF4) at the same time that an SAP process is
attempting to access storage devices attached
to this card. The chance of a system hang is
increased if the following cards are used for
heavy network traffic:
X4447A-Z, PCI-e Quad-port Gigabit
Ethernet Adapter UTP
X1027A-Z1, PCI-e Dual 10 Gigabit Ethernet
Fiber XFP Low profile Adapter
There is no workaround. Check for the
availability of a patch for this defect.
TABLE 6 Specific Issues and Workarounds Concerning Solaris (Continued)
CR ID Description Workaround
Vista de pagina 39
1 2 ... 35 36 37 38 39 40 41 42 43 44 45 46 47 48

Comentarios a estos manuales

Sin comentarios